Spare / Replacement probes for 6000 Series Coating Thickness Gauges. All probes are supplied with a NIST Traceablecalibration certificate.
Probe Ordering Guide:
F -for ferrous metals (steel and cast iron)
N -for non-ferrous metals (aluminum, copper, titanium, etc.)
FN -for all metal substrates - Automatically recognizes the substrate and takes a measurement
Integral Probes: PRBF, PRBN, PRBFN, PRBFT
| F, N, FN | FT | |
|---|---|---|
| Range: | 0 - 60 mils 0 - 1500 | 0 - 250 mils 0 - 6 mm 0 - 6000 |
| *Accuracy: | (0.05 mils + 1%) 0 - 2 mils (0.1 mils + 1%) > 2 mils (1 + 1%) 0 - 50 (2 + 1%) > 50 | (0.5 mils + 1%) 0 - 100 mils (0.5 mil + 3%) > 100 mils (0.01 mm + 1%) 0 - 2.5 mm (0.01 mm + 3%) > 2.5 mm |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
| FS, NS, FNS | NAS | |
|---|---|---|
| Range: | 0 - 60 mils 0 - 1500 | 0 - 25 mils 0 - 625 |
| *Accuracy: | (0.05 mils + 1%) 0 - 2 mils (0.1 mils + 1%) > 2 mils (1 + 1%) 0 - 50 (2 + 1%) > 50 | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 um + 1%) 0 - 100 um (2 um + 3%) > 100 um |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
| FXS Xtreme | |
|---|---|
| Range: | 0 - 80 mils 0 - 2000 |
| *Accuracy: | (0.05 mils + 1%) 0 - 2 mils (0.1 mils + 1%) > 2 mils (1 + 1%) 0 - 50 (2 + 1%) > 50 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
| PRBFRS, PRBNRS, PRBFNRS | |
|---|---|
| Range: | 0 - 60 mils 0 - 1500 |
| *Accuracy: | (0.05 mils + 1%) 0 - 2 mils (0.1 mils + 1%) > 2 mils (1 + 1%) 0 - 50 (2 + 1%) > 50 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Cabled Probe for Duplex Coatings: PRBFNDS
| PRBFNDS | |
|---|---|
| Range | 0 - 60 mils 0 - 1500 |
| Minimum Zinc Thickness | 0.5 mil (13 ) |
| Paint Layer Accuracy Mils | (0.05 mils + 1%) 0 - 2 mils (0.1 mils + 1%) > 2 mils |
| Paint Layer Accuracy Microns | (1 + 1%) 0 - 50 (2 + 1%) > 50 |
| Zinc Layer Accuracy Mils | (0.1 mils + 1%) 0.5 - 2 mils (0.2 mils + 1%) > 2 mils |
| Zinc Layer Accuracy Microns | (2 um + 1%) 13 - 50 um (4 um + 1%) > 50 um |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Cabled 0 Microprobes: PRBF0S, PRBN0S
| PRBF0S, PRBN0S | |
|---|---|
| Range: | 0 - 45 mils 0 - 1150 |
| *Accuracy: | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Cabled 45 Microprobes: PRBF45S, PRBN45S
| F45S | N45S | |
|---|---|---|
| Range: | 0 - 45 mils 0 - 1150 | 0 - 25 mils 0 - 625 |
| *Accuracy: | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Cabled 90 Microprobes:PRBF90S, PRBN90S
| F90S | N90S | |
|---|---|---|
| Range: | 0 - 45 mils 0 - 1150 | 0 - 25 mils 0 - 625 |
| *Accuracy: | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Cabled 90 Extended Length Microprobe: PRBF90ES
| PRBF90ES | |
|---|---|
| Range: | 0 - 45 mils 0 - 1150 |
| *Accuracy: | (0.02 mils + 1%) 0 - 4 mils (0.1 mils + 3%) > 4 mils (.5 + 1%) 0 - 100 (2 + 3%) > 100 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
High-Range Probes: PRBFT, PRBFTS, PRBFTRS, PRBFNTS
| PRBFT, PRBFTS, PRBFTRS, PRBFNTS | |
|---|---|
| Range: | 0 - 250 mils 0 - 6 mm 0 - 6000 |
| *Accuracy: | (0.5 mils + 1%) 0 - 100 mils (0.5 mil + 3%) > 100 mils (0.01 mm + 1%) 0 - 2.5 mm (0.01 mm + 3%) > 2.5 mm |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Ideal for thick protective coatings such as epoxy, rubber, concrete liners, intumescent fireproofing and more: PRBFKS, PRBNKS
| PRBFKS, PRBNKS | |
|---|---|
| Range: | 0 - 500 mils 0 - 13 mm |
| *Accuracy: | (1 mils + 3%) (0.02 mm + 3%) |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Measurenon-conductivecoatings on steel substrates: FHXS Xtreme
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Ideal for measuring thick epoxies, rubbers, fireproofing and other thick protective coatings applied to steel: PRBFJS
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Measures intumescent paint and other thick protective coatings on steel: PRBFLS
| PRBFLS | |
|---|---|
| Range: | 0 - 1.5 inches 0 - 38 mm |
| *Accuracy: | (0.01 in. + 3%) (0.2 mm + 3%) |
| Minimum Surface Area: | 3.25 x 3.25 in. (83 x 83 mm) |
| Minimum Substrate Thickness: | 0.1 in. (2.5 mm) |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Measures very thick coatings on ALL metals: PRBFNGS
| PRBFNGS | |
|---|---|
| Range: | 0 - 2.5 inches 0 - 63.5 mm |
| *Accuracy: | (0.01 in. + 3%) (0.2 mm + 3%) |
| Minimum Surface Area: | 10 x 10 in. (254 x 254 mm) |
| Minimum Substrate Thickness: | 0.2 in. (5 mm) |
| Weight: | 0.8 lb. (0.4 kg) |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
DeFelsko BDYADV-G PosiTector Advanced Gage Body
DeFelsko BDYSTD-G PosiTector Standard Gage Body
DeFelsko SMLINK PosiTector SmartLink Wireless Module
| DeFelsko PosiTector 6000 Coating Thickness Gages - Full Instruction Manual |
| DeFelsko PosiTector 6000 Coating Thickness Gages - Literature |
| DeFelsko PosiTector 6000 Coating Thickness Gages - Quick Guide |
![]() | DeFelsko PosiTector 6000 Probe Details - Online |
![]() | DeFelsko PosiTector 6000 Coating Thickness Gages - Online Instructions Manual |
![]() | DeFelsko Accessories for Inspection Instruments - Online Catalog |