3 Models
DCF-3000FX - Ferrous Only Model
DCN-3000FX - Non-Ferrous Only Model
DCFN-3000FX - Combination Ferrous & Non-Ferrous Model
The 3000FX Series coating thickness gauge is a multifunctional fully menu driven gauge for fast, professional and precise coating thickness measurement for
varnish, paint and electroplated coatings on iron/steel and
varnish, paint and anodising coatings on non-ferrous metals and on austenitic stainless steels
All external probes are machined to ultra-high standards and utilize a unique, hard-metal probe tip which prevents probe wear.
A v-notched footer provides a stable footing on small cylindrical parts, which can be removed to expose a "micro-probe" sensor perfect to measure on small surfaces and parts.
Where to use the 3000FXcoating thickness gauge Series
Wherever coatings are applied whether on visual and aesthetic grounds, to prevent corrosion protection, or for functional and mechanical reasons the coating thickness represents an essential quality feature. The 3000FX Series is ideal for speedy, non-destructive and exceptionally precise coating thickness measurement.| Measuring principle | magnetic induction principle (Ferrous) eddy-current principle (Non-Ferrous) |
| Range | 0 - 60.00 mils 0 - 1500 m |
| Accuracy | 0.04 mils / 1m + 1% of reading |
| Resolution | Refer to RESOLUTION TABLE, above |
| Display | back-light, 4-digit alphanumeric, digit height 10mm |
| Minimum Measuring Area | 0.2" x 0.2" (5 mm x 5 mm) |
| Minimum Curvature Radius | convex: 0.12" (3 mm), concave: 0.2" (5 mm) |
| Minimum Substrate Thickness | Ferrous: 20 mils / 0.5 mm Non-Ferrous: 2 mils / 50 m |
| Calibration | factory calibration, zero calibration, foil calibration, offset-function: addition or subtraction of a constant value |
| Memory | 80 readings |
| Statistics Program | Number of readings, mean value, standard deviation, maximum and minimum reading of max. 10,000 readings |
| Data Output | Infrared IrDA Standard |
| Operating Temp. | 32 F - 122 F / 0 C - 50 C |
| Surface Temp. | 5 F - 140 F / -15 C - 60 C (standard) 5 - 302 F / 15 - 150 C (w/optional footer) |
| Storage Temp. | -4 F to 140 F / -20 C to +60 C |
| Power | 2 AA 1.5V |
| Dimensions | 5.6" x 2.5" x 1.2" (140 mm x 62 mm x 30 mm) |
| Weight | 7 oz (200 g) (gauge + probe) |
| Protection Class | IP 52 (proof against dust and dripping water) |
| Standards | DIN, ISO, ASTM, BS |
| Warranty | 1 Year |
| Calibration Certificate | Included |
| Minimum Radius for Convex Surfaces | 0.2" (5 mm) | |
| Minimum Radius for Concave Surfaces | 2" (50mm) | |
| Minimum Headroom | 4" (100 mm) | |
| Minimum Sample Diameter | 0.5" (13 mm) | |
| Minimum Substrate Thickness - F Minimum Substrate Thickness - NFe | 20 mils (0.5 mm) 2 mils (50 m) |
| Mils | Microns (m) | ||
| 0.00 - 9.99 mils | 0.01 mils | 0.0 - 99.9 m | 0.1 m |
| 10.00 - 24.98 mils | 0.02 mils | 100.0 - 249.8 m | 0.2 m |
| 25.00 - 49.95 mils | 0.05 mils | 250.0 - 499.5 m | 0.5 m |
| 50.0 - 99.9 mils | 0.1 mils | 500 - 999 m | 1 m |
| 1.000 - 1.998 mm | 0.002 mm | ||
| Checkline 3000EZ-E Series Coating Thickness Gauge - Data Sheet |